Front controller

The front controller (FC) is the brain of the car. It owns the global governor, sequences the high-voltage contactors, reads the driver's pedals and steering, computes torque, and runs the two AMK inverter state machines. It also exchanges status with the LV controller and publishes telemetry that the Raspberry Pi logger records.

The FC is the only vehicle ECU that transmits on both CAN buses:

  • Vehicle CAN (CAN2) — dashboard, LV, TMS, BMS, telemetry.
  • Powertrain CAN (CAN1) — left and right inverters.

It works with the other boards:

  • Dashboard — sends the driver's requested startup step and receives acknowledgments.
  • LV controller — supplies FC power and controls the inverter supply and shared switch.
  • Raspberry Pi — logs CAN telemetry and can request ECU flashing; it does not command HV or torque.

What runs when

Src/app.cc creates three FreeRTOS tasks after initialization:

Task Period Priority Work
task_100hz 10 ms 3 Read sensors; check pedal plausibility; run global governor; update accumulator, vehicle dynamics and motors; send contactor, brake-light, switch and inverter commands
task_10hz 100 ms 2 Toggle debug LED; mirror LV fault LEDs; check DBC hash; read suspension and HSD current; send FcStatus, DashCommand, alerts and debug frames
task_1hz 1000 ms 1 Send FcGitHash

main() also drives dashboard power high once at boot. The dashboard stays powered as long as the FC has power.

Global governor

The governor is the top-level startup state machine. It is documented in full, with its transition table and dashboard handshake, on Startup and the global governor.

In one sentence: the dashboard sends a requested screen state, and the governor turns that request into accumulator and motor enable commands, a torque permission, and a ready-to-drive sound.

Accumulator

The accumulator object owns the three contactor commands and validates the BMS feedback. Its state is reported in FcStatus.AccumulatorState.

stateDiagram-v2
    [*] --> IDLE
    IDLE --> STARTUP_ENSURE_OPEN: command ENABLED
    STARTUP_ENSURE_OPEN --> STARTUP_CLOSE_NEG: all feedback open
    STARTUP_CLOSE_NEG --> STARTUP_HOLD_CLOSE_NEG: negative closed
    STARTUP_HOLD_CLOSE_NEG --> STARTUP_CLOSE_PRECHARGE: 100 ms
    STARTUP_CLOSE_PRECHARGE --> STARTUP_HOLD_CLOSE_PRECHARGE: precharge feedback closed
    STARTUP_HOLD_CLOSE_PRECHARGE --> STARTUP_CLOSE_POS: > 90% and ≥ 10 s
    STARTUP_CLOSE_POS --> STARTUP_HOLD_CLOSE_POS: positive closed
    STARTUP_HOLD_CLOSE_POS --> STARTUP_OPEN_PRECHARGE: 100 ms
    STARTUP_OPEN_PRECHARGE --> RUNNING: precharge open
    RUNNING --> ERROR: feedback mismatch
    STARTUP_CLOSE_NEG --> ERROR: wrong feedback
    STARTUP_HOLD_CLOSE_NEG --> ERROR: wrong feedback
    STARTUP_CLOSE_PRECHARGE --> ERROR: wrong feedback
    STARTUP_HOLD_CLOSE_PRECHARGE --> ERROR: wrong feedback
    STARTUP_CLOSE_POS --> ERROR: wrong feedback
    STARTUP_HOLD_CLOSE_POS --> ERROR: wrong feedback
    ERROR --> SHUTDOWN: command OFF
    RUNNING --> SHUTDOWN: command OFF
    SHUTDOWN --> IDLE: precharge < 10% after more than 5 s

Important details:

  • Feedback is inverted. true means a contactor is open; false means it is closed.
  • Precharge voltage is measured by an FC analog input and averaged to reduce noise.
  • Pack voltage comes from Pack_State; maximum pack voltage comes from Pack_SOC. If a matching pair stops arriving for 500 ms, precharge completion is blocked.
  • A wrong contactor state in most startup steps latches AccumulatorContactorWrongState and enters ERROR. STARTUP_ENSURE_OPEN only waits for all feedback to read open, so a welded contactor there stalls startup without a fault. Missing feedback also just waits.
  • The low-SOC check is commented out.

Motors and inverters

The motor coordinator owns two Amk objects, one per inverter, plus a starter state machine for each. Its state is reported in FcStatus.MotorState.

stateDiagram-v2
    [*] --> IDLE
    IDLE --> STARTING: command ENABLED
    STARTING --> SWITCHING_INVERTER_ON: both starters succeed
    STARTING --> ERROR: starter error
    SWITCHING_INVERTER_ON --> RUNNING: LV reports switch closed
    RUNNING --> ERROR: either AMK reports error
    RUNNING --> IDLE: command OFF
    ERROR --> IDLE: command OFF

The AMK state machine is the low-level per-inverter sequence:

OFF → SYSTEM_READY → STARTUP_bDCON → STARTUP_bENABLE
    → STARTUP_bINVERTER → STARTUP_X140 → RUNNING

The starter layer waits for the inverter's ready and DC-on acknowledgments before moving through the AMK states. Both motors must reach STARTUP_X140 before the FC asks the LV controller to close the shared inverter switch. The FC proceeds to RUNNING when LvStatus.MotorControllerSwitchClosed is true.

While running, the FC sends each inverter a setpoint frame containing enable bits, a speed request and positive/negative torque limits. Feedback arrives in Inv1/2_ActualValues1/2.

Driver inputs and torque

The FC reads two accelerator pedal sensors, brake pressure, steering angle, four wheel-speed inputs, suspension travel and the precharge monitor.

Driver torque is computed at 100 Hz:

Condition Result
Both APPS sensors disagree by more than 10% Torque request = 0; AppsImplausible alert
APPS above 25% while brake is pressed Torque request = 0 until APPS falls below 5% (EV47Active)
Otherwise Request = main APPS percentage

IsBrakePressed() uses the FC's own brake sensor and a threshold of 10%. This is the brake check that lets the governor enter RUNNING.

The pedal request then goes through the active pedal map (linear by default, quadratic available) and into vehicle dynamics. Dynamics produces a left and right request with opposite speed signs; the torque limits are what actually restrict drive torque. Torque vectoring is disabled and the traction-control scale factor is currently fixed at 1.

Outputs

Output Controlled by
Accumulator contactors ContactorCommand over vehicle CAN
Inverter enable, speed and torque Inv1/2_Setpoints1 over powertrain CAN
Shared inverter switch request InverterSwitchCommand over vehicle CAN
Brake light request LvCommand.BrakeLightEnable over vehicle CAN
Dashboard power DASHBOARD_HSD_EN GPIO, set high at boot
Ready-to-drive sound RTDS_EN GPIO, on for ~2 s after entering RUNNING
IMD and BMS warning LEDs GPIOs mirrored from LvAlerts; default on if no alert frame
Debug LED Toggled at 10 Hz
HSD current sensing GPIO mux and ADC sampled locally; values are not transmitted

Diagnostics

The FC sends FcAlerts with bits for pedal plausibility, accumulator state, motor start/run errors, dashboard boot timeout, CAN errors, missing inverter CAN and HSD overcurrent. The HSD overcurrent bit is always false in this revision. FcStatus carries the governor, accumulator, motor and per-inverter states plus a DBC-valid flag.

The DBC-valid flag compares the FC's generated hash with the LV controller's hash. It is telemetry only; it does not block startup.