CAN communication
All coordination between boards happens over two classic CAN buses, both configured for 500 kbit/s:
| Bus | Nodes | Purpose |
|---|---|---|
| Vehicle | Dashboard, front controller, LV controller, TMS, BMS, IMD, GPS, Raspberry Pi | Driver requests, power state, contactors, temperatures, telemetry |
| Powertrain | Front controller, left inverter, right inverter, Raspberry Pi (logger, receive-only) | Inverter enable, speed/torque setpoints, inverter feedback |
The front controller is the bridge between the two control domains: it reads driver and dashboard inputs from the vehicle bus and sends motor commands on the powertrain bus.
How message IDs are built
The DBC header documents an intended ID convention:
| Digit | Meaning |
|---|---|
| First | 1 special, 2 periodic, 3 sensor, 4 debug |
| Second | ECU the message belongs to, not always the sender: 0 front controller, 1 LV controller, 2 TMS, 3 dashboard, 4 Raspberry Pi |
| Third (periodic only) | 0 command, 1 status, 2 alerts |
Many IDs follow it: FcStatus is 201 (periodic, front controller, status),
LvCommand is 210 (periodic, belongs to the LV controller, sent by the
FC), DashCommand is 230 (sent by the FC, belongs to the dashboard),
LvAlerts is 212, and Accumulator_Soc is 300 (sensor, front
controller).
The convention is not enforced. Some periodic frames use the third digit for
another purpose: FcCounters is 203, TMSValues is 204,
InverterSwitchCommand is 213, and LvDcdc is 214. InverterStatus (241)
fits the 2x1 shape but is sent by the FC to the dashboard. TuningParams
(340) fits 3xn but carries configuration, not sensor data.
The 1570–1574 block is a separate BMS command/status range: 1570 is FC-sent and 1571–1574 are BMS-sent. Always decode by the DBC message name and signals, not by the ID digits alone.
The BMS, IMD and GPS add 11-bit frames outside this convention. The TMS sends
its thermistor broadcast, BmsBroadcast, as a 29-bit extended frame
(0x1839F380). The DBC also defines ThermistorBroadcast (0x18FEF1FE) as a
second 29-bit frame, but the current application does not send it.
Main message flow
flowchart LR
DASH[Dashboard] -->|DashStatus| FC[Front controller]
FC -->|DashCommand| DASH
FC -->|ContactorCommand| BMS[BMS]
BMS -->|Contactor_Feedback<br/>Pack_State · Pack_SOC| FC
FC -->|LvCommand<br/>InverterSwitchCommand| LV[LV controller]
LV -->|LvStatus · LvAlerts| FC
FC -->|Inv1/2_Setpoints1| INV[Inverters]
INV -->|Inv1/2_ActualValues1/2| FC
TMS[TMS] -->|BmsBroadcast| BMS
TMS -->|BmsBroadcast| DASH
The arrows show message flow, not physical wiring. All vehicle-bus nodes are attached to the same shared bus.
The most important startup messages are:
| Message | Sender → receiver | Rate | Purpose |
|---|---|---|---|
DashStatus |
Dashboard → FC | ~50 Hz | Screen state and selected profile |
DashCommand |
FC → dashboard | 10 Hz | Acknowledge startup steps, speed, SOC, reset |
ContactorCommand |
FC → BMS | 100 Hz | Positive, negative and precharge contactor requests |
Contactor_Feedback |
BMS → FC/LV/dashboard | External | Inverted open/closed feedback |
Pack_State |
BMS → FC and dashboard | External | Pack voltage and current |
Pack_SOC |
BMS → FC | External | State of charge and maximum pack voltage |
InverterSwitchCommand |
FC → LV | 100 Hz | Request to close the shared inverter switch |
LvStatus |
LV → FC | 10 Hz | LV state and switch acknowledgment |
Inv1/2_Setpoints1 |
FC → inverters | 100 Hz | Enable bits, speed and torque limits |
Inv1/2_ActualValues1/2 |
Inverters → FC | External | Readiness, speed, current, temperature, error |
FcStatus |
FC → Pi | 10 Hz | Governor, accumulator and motor states |
LvAlerts |
LV → FC/dashboard/Pi | 10 Hz | IMD, BMS and HSD fault flags |
LvCommand, sent by the FC at 100 Hz, carries the brake-light request. Its
receipt is also how the LV controller knows the FC is online. The exact bit
layout and every signal are defined in projects/veh.dbc and
projects/pt.dbc.
Generated C++ types
The DBC files describe the wire format. scripts/cangen turns them into C++
classes for each ECU:
flowchart LR
DBC[veh.dbc / pt.dbc] --> GEN[cangen]
CFG[project config.yaml<br/>node = FC, LVC, TMS or DASH] --> GEN
GEN --> HDR[Inc/generated/can/<br/>*_bus.hpp · *_messages.hpp]
HDR --> APP[Src/app.cc]
Each project gets only the messages it sends or receives. For example, the FC gets vehicle and powertrain headers; the TMS gets only the vehicle bus.
The generated bus provides:
VehBus veh_can{can_base};
veh_can.Send(tx_message);
auto latest = veh_can.GetRxDashStatus(); // latest value, retained
auto cleared = veh_can.PopRxDashStatus(); // latest value, then clear
Latest value, not a queue
CAN reception is a one-message mailbox per message type. A new frame replaces the previous frame of that type.
GetRx...()returns the latest decoded value and keeps it.PopRx...()returns it and clears the slot.- There is no automatic age check or timeout.
This is the most common source of confusion when reading startup code:
has_value() does not mean the sender is alive
A dashboard that sent DashStatus once and then stopped still leaves a
valid value in the mailbox. The front controller will keep reading that
last state unless the application adds its own timeout. Most startup paths
do not add one.
The accumulator is the main exception: it pops Pack_State and Pack_SOC and
invalidates pack voltage if no matching pair arrives for more than 500 ms.
Frames, signals and binary values
These are classic CAN buses, not CAN FD. A frame carries at most 8 data bytes and is identified by an 11-bit or 29-bit ID. The ID names the message, not a destination: every node on the bus sees the frame. Most messages here use 11-bit IDs; the thermistor broadcast from the TMS uses a 29-bit extended ID.
A DBC file describes how the bits inside each frame are interpreted:
- the message ID, length and sender;
- each signal's start bit, width, byte order, signedness, scale, offset, range and unit;
- names for enumerated values.
A signal stores a raw integer. The physical value is:
physical = raw × scale + offset
For example, BppsPercent has scale 0.1 and unit percent. Two details
matter in this repository:
- State numbers are part of the DBC. The FC governor state value
1is not used;WAIT_DRIVER_SELECTis2. - Units are not always what the name suggests. The dashboard's
> 0.20brake check is 0.20 percentage points, not 20 percent.
Watching the bus
With a SocketCAN adapter and the repository checked out:
cd projects
bash monitor_veh.sh # vehicle bus, can1, veh.dbc
bash monitor_pt.sh # powertrain bus, can0, pt.dbc
These scripts configure the interface with ip and open cantools monitor.
They require Linux, iproute2 and cantools. The Linux
interface names are a local convention; they are not the STM32 CAN peripheral
numbers.